Digital Twin#

The key ingredient in a recipe for a reliable infrastructure automation is the rigorous testing of the changes before they are applied to the production environment. And when networks are concerned, the testing is better done in a controlled environment that resembles the production as closely as possible. This is where the Digital Twin feature of Nokia EDA comes into play.

The Digital Twin provides a scalable and flexible simulation platform for testing the changes in a controlled virtual environment, ensuring that your infrastructure remains stable and reliable.

The component that implements the Digital Twin feature is called eda-cx, therefore, you may see us using the CX term when referring to the Digital Twin feature.

If you completed the quickstart, you noticed that the three-node network topology that the Try EDA cluster comes with is in fact powered by the Digital Twin feature. The eda-cx component is responsible for creating a virtual representation of the network, allowing you to test changes without affecting the production environment.

EDA's Digital Twin comes with unique features that set it apart from other network virtualization solutions:

  • Scalability: The Digital Twin uses the Kubernetes platform to horizontally scale the simulation environment to match the size of your network. This means that you can deploy virtual topologies comprising hundreds of nodes and links, and the Digital Twin will schedule the nodes efficiently.
  • Declarative API: As everything else in EDA, the Digital Twin operates in a declarative manner. The TopoNode and TopoLink resources that are used to define the physical topology of the network are also used to define the virtual topology in the Digital Twin. This means that you can use the same resources to define both the physical and virtual topologies, and the Digital Twin will automatically create the virtual representation of the network.
  • Multivendor support: For every vendor device that is supported by EDA, there is a corresponding virtual simulator in the Digital Twin that you can use to create multivendor topologies.1.

EDA's Digital Twin does not use Containerlab nor Clabernetes. It is a purpose-built, production-grade virtual simulation engine that delivers support for massive scale and a tight integration with the EDA platform to achieve the goals of building the virtual replica of a production network.
However, if you want to use EDA with a network topology that is built with Containerlab, you can do so by using the Containerlab integration.

Digital Twin Mode#

When installing EDA software, users can choose whether they want to spin up the EDA cluster for use in the Digital Twin mode or for use with the hardware devices. By default, the cluster is deployed in the "Digital Twin" mode, where the Network Topology created by a user results in virtual simulators deployed for the topology nodes and virtual links wired for the topology links.

To deploy the cluster for use with hardware devices, set the SIMULATE=false in the preferences file during the installation customization.

Warning

As of EDA 25.12.1, once the cluster is deployed, users can't change the mode of the cluster without redeploying it.

To check what mode your EDA cluster is deployed in, you can use the command:

kubectl get -n eda-system engineconfig \
-o custom-columns="SIMULATE MODE:.spec.simulate"
SIMULATE MODE
true

Simulated Network Topologies#

One of the key responsibilities of the Digital Twin system is to create and manage the virtual topologies that typically serve as a virtual replica of the production network allowing users to test and model the network changes, validate the designs, develop automation solutions and much more.

As extensively covered in the Network Topology section, the network topology in EDA is modelled with the TopoNode, TopoLink and TopoBreakout resources. These resources are created by the Network Topology workflow and declaratively define the physical network topology. The three-node fabric we worked on in the Getting Started guide therefore is depicted as follows:

When a user creates the topology resources in an EDA cluster running in the Digital Twin mode, the eda-cx component that is responsible for the simulation network will create the virtual counterparts for the TopoNode and TopoLink resources, namely the SimNode/SimLink resources.
To illustrate this process, let's create a dummy topology with two nodes and one link between them in the net-topo-test namespace that we used in the Network Topology section:

Note, that the workflow spec has nothing specific to the Digital Twin here, it is the same topology input as you would use for the physical topology as well:

apiVersion: topologies.eda.nokia.com/v1alpha1
kind: NetworkTopology
metadata:
  generateName: 2-nodes-
  namespace: net-topo-test
spec:
  operation: replaceAll

  nodeTemplates:
    - name: node
      nodeProfile: srlinux-ghcr-25.10.1
      platform: 7220 IXR-D3L
      labels:
        eda.nokia.com/security-profile: managed
  nodes:
    - name: node1
      template: node
    - name: node2
      template: node

  linkTemplates:
    - name: isl
      type: interSwitch
  links:
    - name: node1-node2
      template: isl
      endpoints:
        - local:
            node: node1
            interface: ethernet-1-1
          remote:
            node: node2
            interface: ethernet-1-1

Copy paste this command in your terminal to create the topology in the net-topo-test namespace:

cat << 'EOF' | kubectl create -f -
apiVersion: topologies.eda.nokia.com/v1alpha1
kind: NetworkTopology
metadata:
  generateName: 2-nodes-
  namespace: net-topo-test
spec:
  operation: replaceAll

  nodeTemplates:
    - name: node
      nodeProfile: srlinux-ghcr-25.10.1
      platform: 7220 IXR-D3L
      labels:
        eda.nokia.com/security-profile: managed
  nodes:
    - name: node1
      template: node
    - name: node2
      template: node

  linkTemplates:
    - name: isl
      type: interSwitch
  links:
    - name: node1-node2
      template: isl
      endpoints:
        - local:
            node: node1
            interface: ethernet-1-1
          remote:
            node: node2
            interface: ethernet-1-1

EOF

As shown in the diagram above, the TopoNode and TopoLink resources represent the network devices and the connections between them. The Digital Twin component in EDA uses these resources to create the virtual simulators and connect them together in a topology that mirrors the physical design. For each TopoNode resource, a corresponding SimNode resource is created, and for each TopoLink resource, a corresponding SimLink resource is created:

Check the Topologies section for more information on how to create and manage the topologies in EDA.

Sim topology resources#

When a user deploys the topology onto the EDA cluster running in the Digital Twin mode, each TopoNode resource is backed by a virtual simulator instance2 and each TopoLink resource is implemented as a datapath connection established in the cluster between the sim node containers. Therefore, for the topology we created above, the Digital Twin will create two simulator instances and connect them with a virtual link:

kubectl get -n net-topo-test simnode
NAME    AGE
node1   15h
node2   15h
kubectl get -n net-topo-test simlink
NAME          AGE
node1-node2   15h

The Digital Twin uses the Kubernetes platform to create a deployment for each TopoNode resource, which in turn creates a pod that runs two containers - the virtual simulator and the datapath wiring component (cxdp). The simulators are scheduled on the EDA's Kubernetes cluster based on resource requests by the Kubernetes scheduler. This ensures that the virtual topology can horizontally scale to match the size of the emulated network.
All Digital Twin simulator nodes run in the eda-system namespace, and can be listed with the following command:

Digital Twin simulator deployments in eda and net-topo-test namespaces
kubectl get -n eda-system deploy -l 'eda.nokia.com/app-group=cx-cluster'
NAME                                    READY   UP-TO-DATE   AVAILABLE   AGE
cx-eda--leaf1-sim                       1/1     1            1           22h
cx-eda--leaf2-sim                       1/1     1            1           22h
cx-eda--spine1-sim                      1/1     1            1           22h
cx-eda--testman-default-sim             1/1     1            1           22h
cx-net-topo-test--node1-sim             1/1     1            1           15h
cx-net-topo-test--node2-sim             1/1     1            1           15h

The deployment name embeds the namespace the virtual simulator runs in and the TopoNode name, so you can easily identify which virtual simulator corresponds to which TopoNode resource.

The Digital Twin automatically created the simulation resources for the TopoNodes representing the node1 and node2 devices, as well as the SimLink resource representing the link between them. However, you may have noticed that our simple topology had no edge links, just the inter-switch link.

Let's see what happens if we add an edge link to node2 and redeploy the topology:

We add a new link template of type edge and create a new TopoLink resource that uses this template to connect to node2:

apiVersion: topologies.eda.nokia.com/v1alpha1
kind: NetworkTopology
metadata:
  generateName: 2-nodes-
  namespace: net-topo-test
spec:
  operation: replaceAll

  nodeTemplates:
    - name: node
      nodeProfile: srlinux-ghcr-25.10.1
      platform: 7220 IXR-D3L
      labels:
        eda.nokia.com/security-profile: managed
  nodes:
    - name: node1
      template: node
    - name: node2
      template: node

  linkTemplates:
    - name: isl
      type: interSwitch
    - name: edge
      type: edge
  links:
    - name: node1-node2
      template: isl
      endpoints:
        - local:
            node: node1
            interface: ethernet-1-1
          remote:
            node: node2
            interface: ethernet-1-1
    - name: node2-ethernet-1-10
      template: edge
      endpoints:
        - local:
            node: node2
            interface: ethernet-1-10
cat << 'EOF' | kubectl create -f -
apiVersion: topologies.eda.nokia.com/v1alpha1
kind: NetworkTopology
metadata:
  generateName: 2-nodes-
  namespace: net-topo-test
spec:
  operation: replaceAll

  nodeTemplates:
    - name: node
      nodeProfile: srlinux-ghcr-25.10.1
      platform: 7220 IXR-D3L
      labels:
        eda.nokia.com/security-profile: managed
  nodes:
    - name: node1
      template: node
    - name: node2
      template: node

  linkTemplates:
    - name: isl
      type: interSwitch
    - name: edge
      type: edge
  links:
    - name: node1-node2
      template: isl
      endpoints:
        - local:
            node: node1
            interface: ethernet-1-1
          remote:
            node: node2
            interface: ethernet-1-1
    - name: node2-ethernet-1-10
      template: edge
      endpoints:
        - local:
            node: node2
            interface: ethernet-1-10

EOF

A couple of interesting observations can be made after this new topology with an added edge link to the node2 device is deployed:

  1. There are no new SimLink resources created for the added edge TopoLink, only the original SimLink representing the inter-switch link is present:

    kubectl get -n net-topo-test topolink
    

    NAME                  AGE
    node1-node2           159m
    node2-ethernet-1-10   159m
    

    kubectl get -n net-topo-test simlink
    

    NAME          AGE
    node1-node2   68s
    

  2. There is a new Interface resource created for the edge link attached to the node2 device, but it is operationally down:

    kubectl get -n net-topo-test interface
    

    NAME                  ENABLED   OPERATIONAL STATE   SPEED   LAST CHANGE   AGE
    node1-ethernet-1-1    true      up                  100G    10m           11m
    node2-ethernet-1-1    true      up                  100G    10m           11m
    node2-ethernet-1-10   true      down                100G    11m           11m
    

The reason for this behavior is that the edge link defined in our topology is a stub, it has no other node to connect to, therefore no SimLink resource is created for it, and the Interface resource remains down. Edge links are typically used to connect to external systems (servers, storage, GPUs, etc) or testing endpoints, and in our case, since there is no such endpoint defined, the edge link remains unconnected.
To bring the edge link up, a user would need to define a Sim Node that will represent the external system and connect the SimLink to it. This is the topic of the next section.

Sim nodes#

As we have identified earlier in this section, the Digital Twin in EDA automatically creates SimNode resources for each TopoNode and SimLink resource for each TopoLink that has both endpoints (local and remote) defined. The Digital Twin won't create a SimLink resource for edge TopoLinks, as they by default only have a local endpoint defined and as such don't have a remote endpoint to connect to.

However, the Network Topology workflow allows users to define custom Sim Nodes that can be used as a remote endpoint for edge TopoLinks. This way, users can connect edge links to a simulated external system in the Digital Twin.

Building on top of our previous example, let's enhance our topology spec by defining a Sim Node that will be represented as a container image running off of ghcr.io/srl-labs/network-multitool:latest image and connect the edge link on node2 to it:

The changes to the workflow spec include populating the .spec.simulation container and defining the simulation node template and its instance, the same way as we defined templates and instances for the nodes and links of the topology.

In the .spec.simulation.simNodeTemplates section we define a new sim node template of type Linux which represents a generic Linux container with the specified container image. In the .spec.simulation.simNodes section we create an instance of the sim node template we just defined under the name server2.
Finally, we update the edge link definition to feature the sim block in its endpoints list that references the newly created sim node and the interface name inside it.

apiVersion: topologies.eda.nokia.com/v1alpha1
kind: NetworkTopology
metadata:
  generateName: 2-nodes-
  namespace: net-topo-test
spec:
  operation: replaceAll

  nodeTemplates:
    - name: node
      nodeProfile: srlinux-ghcr-25.10.1
      platform: 7220 IXR-D3L
      labels:
        eda.nokia.com/security-profile: managed
  nodes:
    - name: node1
      template: node
    - name: node2
      template: node

  linkTemplates:
    - name: isl
      type: interSwitch
    - name: edge
      type: edge
  links:
    - name: node1-node2
      template: isl
      endpoints:
        - local:
            node: node1
            interface: ethernet-1-1
          remote:
            node: node2
            interface: ethernet-1-1
    - name: node2-ethernet-1-10
      template: edge
      endpoints:
        - local:
            node: node2
            interface: ethernet-1-10
          sim:
            simNode: server2
            simNodeInterface: eth1
  simulation:
    simNodeTemplates:
      - name: multitool
        type: Linux #(1)!
        image: ghcr.io/srl-labs/network-multitool:latest
    simNodes:
      - name: server2
        template: multitool
  1. The .spec.simulation.simNodeTemplates[].type field defines the type of the Sim Node. Two types are currently supported: Linux and TestMan. The Linux type represents a generic Linux container that can run any container image specified in the image field.

    The TestMan type represents a special container image that is purpose-built to assist in testing and validation in the EDA Digital Twin environment. See the TestMan section below for more details.

cat << 'EOF' | kubectl create -f -
apiVersion: topologies.eda.nokia.com/v1alpha1
kind: NetworkTopology
metadata:
  generateName: 2-nodes-
  namespace: net-topo-test
spec:
  operation: replaceAll

  nodeTemplates:
    - name: node
      nodeProfile: srlinux-ghcr-25.10.1
      platform: 7220 IXR-D3L
      labels:
        eda.nokia.com/security-profile: managed
  nodes:
    - name: node1
      template: node
    - name: node2
      template: node

  linkTemplates:
    - name: isl
      type: interSwitch
    - name: edge
      type: edge
  links:
    - name: node1-node2
      template: isl
      endpoints:
        - local:
            node: node1
            interface: ethernet-1-1
          remote:
            node: node2
            interface: ethernet-1-1
    - name: node2-ethernet-1-10
      template: edge
      endpoints:
        - local:
            node: node2
            interface: ethernet-1-10
          sim:
            simNode: server2
            simNodeInterface: eth1
  simulation:
    simNodeTemplates:
      - name: multitool
        type: Linux #(1)!
        image: ghcr.io/srl-labs/network-multitool:latest
    simNodes:
      - name: server2
        template: multitool

EOF

Applying this topology will result in the Digital Twin creating a new SimNode resource, the associated k8s deployment for it and the SimLink object for the edge link that now has both local and sim (remote) endpoints defined:

The newly created SimNode resource is now present in the namespace:

kubectl get -n net-topo-test simnode
NAME      AGE
node1     19m
node2     19m
server2   19m

And the corresponding simulator deployments are created in the eda-system namespace:

kubectl get -n eda-system deploy -l 'eda.nokia.com/app-group=cx-cluster' \
  -l 'cx-node-namespace=net-topo-test'
NAME                            READY   UP-TO-DATE   AVAILABLE   AGE
cx-net-topo-test--node1-sim     1/1     1            1           20m
cx-net-topo-test--node2-sim     1/1     1            1           20m
cx-net-topo-test--server2-sim   1/1     1            1           20m

The same number of TopoLink resources are present as before:

kubectl get -n net-topo-test topolink
NAME                  AGE
node1-node2           159m
node2-ethernet-1-10   159m

But now there is a new SimLink resource connecting node2 and server2 that was not present before until we added a SimNode to connect to:

kubectl get -n net-topo-test simlink
NAME                  AGE
node1-node2           23m
node2-ethernet-1-10   23m

Everything looks great, but the Interface resource node2-ethernet-1-10 still shows as operationally down:

kubectl get -n net-topo-test interface
NAME                  ENABLED   OPERATIONAL STATE   SPEED   LAST CHANGE   AGE
node1-ethernet-1-1    true      up                  100G    22m           24m
node2-ethernet-1-1    true      up                  100G    22m           24m
node2-ethernet-1-10   true      down                100G    23m           24m

Why? Because for SimNode of type Linux, EDA's Digital Twin does not automatically bring up the interfaces that we specified in the topology input.
If we connect to the shell of the server2 container image we will see that the eth1 interface that we specified in the links section of our topology is operationally down. We can bring it up manually with the standard Linux commands:

connecting to the shell of the server2 SimNode
kubectl -n eda-system exec -it \
$(kubectl get -n eda-system pods -l 'cx-node-namespace=net-topo-test' \
-l 'cx-pod-name=server2' \
-o jsonpath='{.items[].metadata.name}') \
-- bash
[*]─[cx-net-topo-test--server2-sim-58cb56dd56-sgh6r]─[/]
└──> ip link show eth1
3: eth1@eth1-cx: <BROADCAST,MULTICAST,M-DOWN> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    link/ether 5e:80:14:5e:bf:6f brd ff:ff:ff:ff:ff:ff

Let's bring up the interface with the ip link set command:

[*]─[cx-net-topo-test--server2-sim-58cb56dd56-sgh6r]─[/]
└──> ip link set eth1 up

Immediately after that we can see that the Interface resource for the ethernet-1-10 port on node2 is now operationally up:

kubectl get -n net-topo-test interface
NAME                  ENABLED   OPERATIONAL STATE   SPEED   LAST CHANGE   AGE
node1-ethernet-1-1    true      up                  100G    37m           38m
node2-ethernet-1-1    true      up                  100G    37m           38m
node2-ethernet-1-10   true      up                  100G    7s            38m

Now you know how to define SimNodes in the Network Topology workflow and connect edge links to them.

Connections topology#

In the Sim Nodes section we described how users can define custom Sim Nodes in the .spec.simulation.simNodes section of the Network Topology workflow spec and connect edge links to them by providing the sim block in the link endpoints. This way, users can selectively attach edge links to the simulated nodes, however, this approach may become tedious when there are many edge links to be connected in the same way.
For example, when you want to connect ports ethernet-1-1 on all nodes to a single Sim Node that represents a testing agent or a traffic generator. This is the case when the TestMan is used as a Sim Node to which multiple edge links can be connected simultaneously. To simplify the process of connecting multiple edge links to a single Sim Node, the Digital Twin supports the concept of a connection topology.

The connection topology is defined in the .spec.simulation.topology section of the Network Topology workflow spec. Here, users can define the rules that specify which nodes and interfaces should be connected to which Sim Node and which Sim Node interface. The rules support wildcard patterns to match multiple nodes and interfaces, allowing for a concise definition of the connections.

Let's work through a set of connection topologies examples that showcase the capabilities and use cases of this feature.

The previous example in the Sim Nodes section showed how to connect the edge link ethernet-1-10 on node2 to a Sim Node named server2. The same connection can be defined with the connection topology as follows (and then no sim block is needed in the link definition):

spec:
  simulation:
    topology:
      - node: "node2"
        interface: "ethernet-1-10"
        simNode: server2
        simNodeInterface: "eth1"

The .spec.simulation.topology section defines a list of connection pairs that specify which node and interface should be connected to which Sim Node and Sim Node interface. For example, here is how several node/interface pairs can be defined:

spec:
  simulation:
    topology:
      - node: "node1"
        interface: "ethernet-1-10"
        simNode: server1
        simNodeInterface: "eth1"
      - node: "node2"
        interface: "ethernet-1-10"
        simNode: server2
        simNodeInterface: "eth1"

A more interesting use case where connection topology shines is when wildcards are used in the node and/or interface fields. For example, to connect all edge interfaces on node1 to a single Sim Node named server1, the following connection topology can be defined:

spec:
  simulation:
    topology:
      - node: "node1"
        interface: "*"
        simNode: server1

Note, how * is used in the interface field to match all interfaces on node1. The simNodeInterface field is omitted here, so the Digital Twin will automatically assign the interfaces on the Sim Node in the order they are connected using the eth0, eth1, eth2, ... naming convention.

Another popular use case is to connect the same interface on all nodes to a single Sim Node. For example, to connect the ethernet-1-10 interface on all nodes to a Sim Node named testman-default, the following connection topology can be defined:

spec:
  simulation:
    topology:
      - node: "*"
        interface: "ethernet-1-10"
        simNode: testman-default

Here, the wildcard * is used in the node field to match all nodes in the topology while the interface field specifies the ethernet-1-10 value. This results in all ethernet-1-10 interfaces on all nodes being connected to the testman-default Sim Node. As before, since the Sim Node interface is not specified, the Digital Twin will automatically assign the interfaces on the Sim Node in the order they are connected.

And lastly, a fully wildcarded connection topology can be defined to connect all edge interfaces on all nodes to a single Sim Node. We use this connection mode with the Try EDA topology for example, where we need to connect all edge interfaces on all nodes to the testman-default Sim Node to make all links up and running:

spec:
  simulation:
    topology:
      - node: "*"
        interface: "*"
        simNode: testman-default

TestMan#

In a lot of cases, the simulated topology benefits from having emulated client devices that can be used to test the connectivity and functionality of the network. Containers running iperf, ICMP pings, HTTP clients, and other tools dear to network engineers are typically found in these emulated clients.

While we showed above how users can define a Sim Node of type Linux and use any container image to run the testing tools, it might not be very convenient to run a standalone container for each access port in the topology. And while it is possible to use one generic Linux container and create VRFs and namespaces inside it, the burden of managing this configuration falls on the user.
Another tension point is the API. The iPerfs, ICMPs and curls of the world don't have a native support for REST or gRPC API to allow a system to programmatically control the test execution and retrieve the results.

These challenges and limitations served as a motivation to create the TestMan - a container image that is purpose-built to assist in testing and validation in the EDA Digital Twin environment.
Having ownership of the TestMan allows us to tightly integrate it with the EDA Digital Twin and provide a seamless experience for users.

A single TestMan container emulates many clients

In fact, the "Try EDA" topology that is featured in the Getting Started guide leverages the TestMan as the emulated clients for all edge links in the topology.

TestMan container in Try EDA topology

To define the TestMan SimNode in the Network Topology users need to set the type of the Sim Node template to TestMan as follows:

Defining TestMan SimNode in Network Topology workflow (snippet)
spec:
  simulation:
    topology:
      - node: "*"
        interface: "*"
        simNode: testman-default
    simNodeTemplates:
      - name: default
        type: TestMan #(2)!
    simNodes:
      - name: testman-default #(1)!
        template: default
  1. Currently edactl tool expects the TestMan node to be named testman-default.
  2. The .spec.simulation.simNodeTemplates[].type field is set to TestMan to indicate that this Sim Node template represents a TestMan container and not just a generic Linux container.

TestMan interfaces#

When the TestMan node is defined in the topology, the Digital Twin automatically creates and manages the interfaces inside the TestMan container to match the number of connections made to it. This will cause every TopoLink to be in the operational up state:

kubectl -n eda get topolink \
-o custom-columns="NAME:.metadata.name,NAMESPACE:.metadata.namespace,STATE:.status.operationalState"
NAME                 NAMESPACE   STATE
leaf1-2-e1212        eda         up
leaf1-e1011          eda         up
leaf1-ethernet-1-3   eda         up
leaf1-ethernet-1-4   eda         up
leaf1-ethernet-1-5   eda         up
leaf1-ethernet-1-6   eda         up
leaf1-ethernet-1-7   eda         up
leaf1-ethernet-1-8   eda         up
leaf1-ethernet-1-9   eda         up
leaf1-spine1-1       eda         up
leaf1-spine1-2       eda         up
leaf2-e1011          eda         up
leaf2-ethernet-1-3   eda         up
leaf2-ethernet-1-4   eda         up
leaf2-ethernet-1-5   eda         up
leaf2-ethernet-1-6   eda         up
leaf2-ethernet-1-7   eda         up
leaf2-ethernet-1-8   eda         up
leaf2-ethernet-1-9   eda         up
leaf2-spine1-1       eda         up
leaf2-spine1-2       eda         up

However, without any services deployed in EDA, the edge interfaces inside the TestMan container will not be configured with any IP/MAC addresses:

edactl -n eda testman get-edge-if all
No EdgeInterfaces found

edactl -n <namespace> testman is the command line interface to interact with the TestMan features.

If you were to create a Fabric and a Virtual Network in EDA that would target the edge interfaces connected to the TestMan, the Digital Twin would automatically configure the interfaces inside the TestMan container with the appropriate addressing.

Creating a Fabric and a Virtual Network

If you don't have a Fabric and a Virtual Network created in EDA yet, paste this snippet in your terminal to create them in the eda namespace:

cat << 'EOF' | kubectl apply -f -
apiVersion: fabrics.eda.nokia.com/v1alpha1
kind: Fabric
metadata:
  name: myfabric-1
  namespace: eda
spec:
  leafs:
    leafNodeSelector:
      - eda.nokia.com/role=leaf
  spines:
    spineNodeSelector:
      - eda.nokia.com/role=spine
  interSwitchLinks:
    linkSelector:
      - eda.nokia.com/role=interSwitch
    unnumbered: IPV6
  systemPoolIPV4: systemipv4-pool
  underlayProtocol:
    protocol:
      - EBGP
    bgp:
      asnPool: asn-pool
  overlayProtocol:
    protocol: EBGP

---
apiVersion: services.eda.nokia.com/v1
kind: VirtualNetwork
metadata:
  name: demo-vnet-bd-vlan-10
  namespace: eda
spec:
  bridgeDomains:
    - name: vnet-demo-bd
      spec:
        eviPool: evi-pool
        tunnelIndexPool: tunnel-index-pool
        type: EVPNVXLAN
        vniPool: vni-pool
  vlans:
    - name: vnet-demo-vlan10
      spec:
        bridgeDomain: vnet-demo-bd
        interfaceSelector:
          - eda.nokia.com/role=edge
        vlanID: "10"

EOF

The above snippet creates an EVPN VXLAN fabric and a Layer 2 Virtual Network that uses VLAN 10 on all interfaces labelled with eda.nokia.com/role=edge. Based on this configuration, the Digital Twin will automatically configure the corresponding edge interfaces on the TestMan side to be part of VLAN 10 and assign IP and MAC addresses to them:

edactl -n eda testman get-edge-if all
--------------------------------------------------------------------------------
        Number of EdgeInterfaces found: 17
--------------------------------------------------------------------------------
Namespace           : eda
Name                : eif-lag-leaf1-2-e1212-local-vlan-10
IfResName           : lag-leaf1-2-e1212-local
IfName              : b2
VlanID              : 10
Router              :
BridgeDomain        : vnet-demo-bd
MAC                 : FE:3F:BB:00:00:0B
IPs                 : 10.0.0.12
                    : fd12:3456:789a:1::c
--------------------------------------------------------------------------------
Namespace           : eda
Name                : eif-lag-leaf1-e1011-local-vlan-10
IfResName           : lag-leaf1-e1011-local
IfName              : b3
VlanID              : 10
Router              :
BridgeDomain        : vnet-demo-bd
MAC                 : FE:3F:BB:00:00:08
IPs                 : 10.0.0.9
                    : fd12:3456:789a:1::9
--------------------------------------------------------------------------------
# snipped for brevity
--------------------------------------------------------------------------------
Namespace           : eda
Name                : eif-leaf1-ethernet-1-3-vlan-10
IfResName           : leaf1-ethernet-1-3
IfName              : eth1
VlanID              : 10
Router              :
BridgeDomain        : vnet-demo-bd
MAC                 : FE:3F:BB:00:00:0C
IPs                 : 10.0.0.13
                    : fd12:3456:789a:1::d
--------------------------------------------------------------------------------

The Digital Twin controller knows how to configure LAG interfaces as well, so for the local and multi-node ESI LAGs defined in the topology, TestMan will create the corresponding LAG interfaces and assign them the appropriate addressing as well.

Ping#

As of 25.12.1, TestMan supports ICMP ping tests that can be executed against the edge interfaces. This allows users to quickly validate the connectivity of the simulated network from the client perspective.

To execute a ping test from TestMan, users need to run the edactl -n <ns> testman ping command, that supports the following parameters:

ping dst-ip using edge-interface

Usage:
  edactl testman ping [command]

Available Commands:
  eif-name    ping dst-ip using specified edge-interface
  interface   ping dst-ip using edge-interface identified by interface-resource and qtag
  vrf-name    ping dst-ip using one of the edge-interface from specified vrf

Using the Try EDA topology as an example and the simple Layer 2 Virtual Network we created above, we can execute a ping test from TestMan from one of the edge interfaces to an IP address assigned to another edge interface. For a concrete example, let's validate that the client connected to leaf1:ethernet-1-3 interface can reach the client connected to leaf2:ethernet-1-3 interface. We start by identifying the edge interface name inside TestMan that corresponds to the leaf1-ethernet-1-3 interface resource:

edactl -n eda testman get-edge-if interface leaf1-ethernet-1-3
--------------------------------------------------------------------------------
        Number of EdgeInterfaces found: 1
--------------------------------------------------------------------------------
Namespace           : eda
Name                : eif-leaf1-ethernet-1-3-vlan-10
IfResName           : leaf1-ethernet-1-3
IfName              : eth1
VlanID              : 10
Router              :
BridgeDomain        : vnet-demo-bd
MAC                 : FE:3F:BB:00:00:0C
IPs                 : 10.0.0.13
                    : fd12:3456:789a:1::d
--------------------------------------------------------------------------------

Next, let's identify the IP address assigned to the edge interface connected to leaf2-ethernet-1-3 interface resource:

edactl -n eda testman get-edge-if interface leaf2-ethernet-1-3
--------------------------------------------------------------------------------
        Number of EdgeInterfaces found: 1
--------------------------------------------------------------------------------
Namespace           : eda
Name                : eif-leaf2-ethernet-1-3-vlan-10
IfResName           : leaf2-ethernet-1-3
IfName              : eth5
VlanID              : 10
Router              :
BridgeDomain        : vnet-demo-bd
MAC                 : FE:3F:BB:00:00:0A
IPs                 : 10.0.0.11
                    : fd12:3456:789a:1::b
--------------------------------------------------------------------------------

Great, we have everything we need to run the ping test now:

  • the source edge interface name inside TestMan: eif-leaf1-ethernet-1-3-vlan-10
  • the destination IP address to ping: 10.0.0.11

Let's run the ping test:

edactl -n eda testman ping eif-name eif-leaf1-ethernet-1-3-vlan-10 10.0.0.11
--- timeout: 16.00 sec, interval: 1000000 µsec ---
PING 10.0.0.11 10.0.0.13 &{eda eif-leaf1-ethernet-1-3-vlan-10}: 56(84) bytes of data.
84 bytes from 10.0.0.11: icmp_seq=0 ttl=128 time=2.886ms
--- 10.0.0.11 ping statistics ---
1 packets transmitted, 1 received, 0% packet loss, time 104ms
rtt min/avg/max/mdev = 2.886/2.886/2.886/0.000ms

More TestMan capabilities are coming soon, stay tuned!

Connecting to the Digital Twin Nodes#

By the virtue of being Kubernetes-native, each simulator node in the Digital Twin is represented by a pod that runs the network OS and the datapath component. Therefore, you can connect and expose the simulator nodes using the standard Kubernetes tooling and methods.

For long-term access to the simulated nodes an administrator might create a service and an ingress or loadbalancer resource. This typically requires some additional configuration and infrastructure setup, but achieves persistent access to the selected ports and protocols.

Typically, though, users would want to connect with SSH to the simulator nodes to inspect the configuration, logs or run ad-hoc commands. Start with listing the TopoNodes in your namespace using kubectl. If you are running the Try EDA cluster, you can expect to see the three nodes in the output:

kubectl -n eda get toponodes 
NAME     PLATFORM       VERSION   OS    ONBOARDED   MODE     NPP         NODE     AGE
leaf1    7220 IXR-D3L   25.3.2    srl   true        normal   Connected   Synced   99m
leaf2    7220 IXR-D3L   25.3.2    srl   true        normal   Connected   Synced   99m
spine1   7220 IXR-H2    25.3.2    srl   true        normal   Connected   Synced   99m

As we explained earlier, each TopoNode is backed by a Kubernetes deployment that runs the simulator. These deployments are spawned in the EDA core namespace (eda-system by default) and have the eda.nokia.com/app-group=cx-cluster label set:

kubectl -n eda-system get deploy -l eda.nokia.com/app-group=cx-cluster
NAME                          READY   UP-TO-DATE   AVAILABLE   AGE
cx-eda--leaf1-sim             1/1     1            1           3h32m
cx-eda--leaf2-sim             1/1     1            1           3h32m
cx-eda--spine1-sim            1/1     1            1           3h32m
cx-eda--testman-default-sim   1/1     1            1           3h32m
If you are running the Try EDA cluster, you will see the testman deployment as well. This is a special testing agent that we will cover in a later section.

As per the virtual topology that comes with the Try EDA cluster, we got three simulator deployments for leaf1, leaf2 and spine1 nodes. Using kubectl we can connect to the node's shell and execute the CLI process to get the CLI access:

kubectl --namespace eda-system exec -it \
$(kubectl --namespace eda-system get pods -l cx-pod-name=leaf1 \
-o=jsonpath='{.items[*].metadata.name}') \
-- bash -l -c 'sudo sr_cli'
Defaulted container "leaf1" out of: leaf1, cxdp
Loading environment configuration file(s): ['/etc/opt/srlinux/srlinux.rc']
Welcome to the Nokia SR Linux CLI.

--{ + running }--[  ]--
A:root@leaf1#

But typing in this multiline command is a bit too much for a repetitive process, so here is a little script that you can put in your $PATH to quickly SSH to the desired node by its name:

node-ssh script to connect to a simulator node
#!/bin/bash

# Script to SSH into a specific node in the EDA topology
# Usage: ./node-ssh <node-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]

# provide the TopoNode name as the first argument
# e.g. node-ssh leaf1
NODE_NAME=${1}

# user namespace to look up the TopoNode in
# default is eda
USER_NS=${2:-eda}

# core namespace to cx pods in
# default is eda
CORE_NS=${3:-eda-system}

function list_nodes() {
  kubectl --namespace ${CORE_NS} get pods -l cx-cluster-name=eda \
  -o=jsonpath='{.items[*].metadata.labels.cx-pod-name}' | tr ' ' '\n'
}

if [ -z "${NODE_NAME}" ]; then
  echo "Usage: $0 <node-name> [<namespace>]"
  echo "  Available nodes are:"
  list_nodes | sed 's/^/    /'
  exit 1
fi

NODE_ADDR=$(kubectl -n ${USER_NS} get targetnode "${NODE_NAME}" -o jsonpath='{.spec.address}')
if [ -z "${NODE_ADDR}" ]; then
  echo "Node ${NODE_NAME} not found in namespace ${USER_NS}; available nodes are:"
  list_nodes | sed 's/^/    /'
  exit 1
fi

USERNAME=admin
# SSH to the node from the eda-toolbox pod
kubectl -n ${CORE_NS} exec -it \
  $(kubectl get -n ${CORE_NS} pods \
  -l eda.nokia.com/app=eda-toolbox -o jsonpath="{.items[0].metadata.name}") \
  -- ssh -o StrictHostKeyChecking=no -o UserKnownHostsFile=/dev/null \
  -p 22 "${USERNAME}@${NODE_ADDR}" || {
  echo "Failed to SSH into node ${NODE_NAME} at ${NODE_ADDR}"
  exit 1
}

You can paste this command in your terminal to add the script to /usr/local/bin directory, and make it executable:

cat << 'EOF' | sudo tee /usr/local/bin/node-ssh
#!/bin/bash

# Script to SSH into a specific node in the EDA topology
# Usage: ./node-ssh <node-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]

# provide the TopoNode name as the first argument
# e.g. node-ssh leaf1
NODE_NAME=${1}

# user namespace to look up the TopoNode in
# default is eda
USER_NS=${2:-eda}

# core namespace to cx pods in
# default is eda
CORE_NS=${3:-eda-system}

function list_nodes() {
  kubectl --namespace ${CORE_NS} get pods -l cx-cluster-name=eda \
  -o=jsonpath='{.items[*].metadata.labels.cx-pod-name}' | tr ' ' '\n'
}

if [ -z "${NODE_NAME}" ]; then
  echo "Usage: $0 <node-name> [<namespace>]"
  echo "  Available nodes are:"
  list_nodes | sed 's/^/    /'
  exit 1
fi

NODE_ADDR=$(kubectl -n ${USER_NS} get targetnode "${NODE_NAME}" -o jsonpath='{.spec.address}')
if [ -z "${NODE_ADDR}" ]; then
  echo "Node ${NODE_NAME} not found in namespace ${USER_NS}; available nodes are:"
  list_nodes | sed 's/^/    /'
  exit 1
fi

USERNAME=admin
# SSH to the node from the eda-toolbox pod
kubectl -n ${CORE_NS} exec -it \
  $(kubectl get -n ${CORE_NS} pods \
  -l eda.nokia.com/app=eda-toolbox -o jsonpath="{.items[0].metadata.name}") \
  -- ssh -o StrictHostKeyChecking=no -o UserKnownHostsFile=/dev/null \
  -p 22 "${USERNAME}@${NODE_ADDR}" || {
  echo "Failed to SSH into node ${NODE_NAME} at ${NODE_ADDR}"
  exit 1
}
EOF
sudo chmod +x /usr/local/bin/node-ssh

With the node-ssh script in place, you can connect with ssh to any node in your Digital Twin by its name:

# Usage: ./node-ssh <node-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]
node-ssh spine1

For SimNodes that don't have SSH access (like SimNodes running generic Linux containers), use the node-shell script that opens up a shell in the simulator pod:

node-shell script to open a shell to a simulator node
#!/bin/bash

# Script to open shell into a simnode in EDA CX
# Usage: ./node-shell <simnode-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]

# provide the SimNode name as the first argument
# e.g. node-shell client1

SIMNODE_NAME=${1}

# user namespace to look up the TopoNode in
# default is eda
USER_NS=${2:-eda}

# core namespace to look up cx pods in
# default is eda
CORE_NS=${3:-eda-system}

function list_simnodes() {
  kubectl --namespace ${USER_NS} get simnodes
}

if [ -z "${SIMNODE_NAME}" ]; then
  echo "Usage: $0 <simnode-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]"
  echo "  Available nodes are:"
  list_simnodes | sed 's/^/    /'
  exit 1
fi

# open shell to the cx pod
kubectl -n ${CORE_NS} exec -it \
  $(kubectl get -n ${CORE_NS} pods \
  -l cx-node-namespace/${USER_NS} -l cx-pod-name=${SIMNODE_NAME} -o jsonpath="{.items[0].metadata.name}") -- sh -c "(bash -l || ash | sh)" \
  || {
  echo "Failed to open shell into node ${SIMNODE_NAME} in ${USER_NS} namespace."
  echo "Available nodes are:"
  list_simnodes | sed 's/^/    /'
  exit 1
}

You can paste this command in your terminal to add the script to /usr/local/bin directory, and make it executable:

cat << 'EOF' | sudo tee /usr/local/bin/node-shell
#!/bin/bash

# Script to open shell into a simnode in EDA CX
# Usage: ./node-shell <simnode-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]

# provide the SimNode name as the first argument
# e.g. node-shell client1

SIMNODE_NAME=${1}

# user namespace to look up the TopoNode in
# default is eda
USER_NS=${2:-eda}

# core namespace to look up cx pods in
# default is eda
CORE_NS=${3:-eda-system}

function list_simnodes() {
  kubectl --namespace ${USER_NS} get simnodes
}

if [ -z "${SIMNODE_NAME}" ]; then
  echo "Usage: $0 <simnode-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]"
  echo "  Available nodes are:"
  list_simnodes | sed 's/^/    /'
  exit 1
fi

# open shell to the cx pod
kubectl -n ${CORE_NS} exec -it \
  $(kubectl get -n ${CORE_NS} pods \
  -l cx-node-namespace/${USER_NS} -l cx-pod-name=${SIMNODE_NAME} -o jsonpath="{.items[0].metadata.name}") -- sh -c "(bash -l || ash | sh)" \
  || {
  echo "Failed to open shell into node ${SIMNODE_NAME} in ${USER_NS} namespace."
  echo "Available nodes are:"
  list_simnodes | sed 's/^/    /'
  exit 1
}
EOF
sudo chmod +x /usr/local/bin/node-shell

With the script in place, you can connect to any node in your Digital Twin by its name:

# Usage: ./node-ssh <node-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]
node-ssh spine1

With the node-shell script in place, you can open the shell to any node in your Digital Twin by its name:

# Usage: ./node-shell <node-name> [<user-namespace>:-eda] [<core-namespace>:-eda-system]
node-shell testman-default

Configuring Simulator Resource Requests#

When EDA CX component creates the virtual simulators in the Digital Twin, it creates a Kubernetes deployment for each simulator node in the topology. To guarantee that the simulators have enough resources to run under potentially high load, the deployments are configured with the resource requests for CPU and memory.

For example, if you have the Try EDA cluster deployed, you can check the resource requests for the leaf1 simulator node with the command:

kubectl get pods -n eda-system -l cx-pod-name=leaf1 \
-o custom-columns="POD:.metadata.labels.cx-pod-name,\
CPU_REQUEST:.spec.containers[*].resources.requests.cpu,\
MEM_REQUEST:.spec.containers[*].resources.requests.memory"
POD     CPU_REQUEST   MEM_REQUEST
leaf1   200m,200m     1Gi,250Mi

You will see at least two values reported for the CPU and memory requests. The first value is the resources requested for the simulator node itself, and the second value is the resources requested for the topology wiring service that EDA's Digital Twin uses to connect the simulator nodes in the topology.
In the example above, the leaf1 simulator node requests 200m of CPU and 1Gi of memory for itself, and 200m of CPU and 250Mi of memory for the topology wiring service, resulting in a total of 400m of CPU and 1.25Gi of memory requested per the simulator node of the SR Linux type.

The default values for the resource requests are chosen to ensure that the simulators can run under medium load. However, you may want to adjust the resource requests based on your specific use case and either increase or decrease them. Often, you may want to decrease the default values to save resources in the cluster and fit more simulator nodes, especially if you run development clusters with a limited amount of hardware resources.

EDA allows you to configure CPU and memory requests and limits for the supported simulator types via the Config Engine setting. For example, to change the CPU and memory requests for the SR Linux simulator nodes and the CXDP (topology wiring service), start by entering the edit mode for the Config Engine:

kubectl edit -n eda-system engineconfig

Add the following block to the spec section:

customSettings:
- applicationName: cx
  settings:
  - name: SrlCpuRequest
    value: 100m
  - name: SrlMemoryRequest
    value: 500Mi
  - name: CxdpCpuRequest
    value: 50m
  - name: CxdpMemoryRequest
    value: 200Mi

This will change the default requests for the SR Linux simulator nodes and the CXDP container.

After editing the Config Engine resource, you need to redeploy the topology for the changes to take effect.

Full list of setting names for the CX application
Setting Name Default Value Description
Nokia SR Linux
SrlCpuRequest 200m SR Linux CPU request
SrlMemoryRequest 1Gi SR Linux Memory request
SrlCpuLimit SR Linux CPU limit
SrlMemoryLimit SR Linux Memory limit
Nokia SR OS
SrosCpuRequest 200m SR OS CPU request
SrosMemoryRequest 1Gi SR OS Memory request
SrosCpuLimit SR OS CPU limit
SrosMemoryLimit SR OS Memory limit
Cisco NX OS
NxosCpuRequest 200m NX-OS CPU request
NxosMemoryRequest 1Gi NX-OS Memory request
NxosCpuLimit NX-OS CPU limit
NxosMemoryLimit NX-OS Memory limit
Arista EOS
EosCpuRequest 200m EOS CPU request
EosMemoryRequest 1Gi EOS Memory request
EosCpuLimit EOS CPU limit
EosMemoryLimit EOS Memory limit
Nokia EDA Edge Sim
EdgeSimCpuRequest 200m EdgeSim CPU request
EdgeSimMemoryRequest 500Mi EdgeSim Memory request
EdgeSimCpuLimit EdgeSim CPU limit
EdgeSimMemoryLimit EdgeSim Memory limit
Nokia EDA CXDP
CxdpCpuRequest 200m CXDP CPU request
CxdpMemoryRequest 250Mi CXDP Memory request
CxdpCpuLimit CXDP CPU limit
CxdpMemoryLimit CXDP Memory limit

After editing the Config Engine resource and redeploying the topology, you can check that the new values have been applied:

kubectl get pods -n eda-system -l cx-pod-name=leaf1 \
-o custom-columns="POD:.metadata.labels.cx-pod-name,\
CPU_REQUEST:.spec.containers[*].resources.requests.cpu,\
MEM_REQUEST:.spec.containers[*].resources.requests.memory"
POD     CPU_REQUEST   MEM_REQUEST
leaf1   100m,50m      500Mi,100Mi

  1. EDA does not bundle the virtual simulators for the 3rd-party vendors. Users should obtain the simulators themselves and made them available to the Digital Twin. 

  2. Like Nokia SR Linux, Nokia SR OS (SR-SIM) or third-party vendor simulator, e.g. Arista EOS.